代码 CALL: Serial Communication Transmission Error
问题描述与安全警告
Yaskawa A1000 AC Drive 触发了严重的 Serial Communication Transmission Error 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Code type: Alarm / minor fault Manual section: Yaskawa A1000 Troubleshooting Communications wiring is faulty, there is a short circuit, or something is not connected properly. - Check for wiring errors. - Correct the wiring. - Check for disconnected cables and short circuits. Repair as needed. Programming error on the master side. Check communications at start-up and correct programming errors. Communications circuitry is damaged. - Perform a self-diagnostics check. - If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or your nearest sales representative. Termination resistor setting is incorrect. A termination resistor must be installed at both ends of a communication line. Slave drives must have the internal termination resistor switch set correctly. Place DIP switch S2 to the ON position.
Source: Yaskawa AC Drive A1000 High Performance Vector Control Drive Technical Manual (SIEP C710616 21H)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Yaskawa A1000 AC Drive 警报
由 Yaskawa 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 A1000 AC Drive 出现类似 CALL 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 280 Yaskawa A1000 AC Drive 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code CALL.
Need a searchable reference for more Yaskawa A1000 AC Drive manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026