代码 dEv (Alarm): Speed Deviation (when using a PG option card and AOLV/PM without PG)

问题描述与安全警告

Yaskawa A1000 AC Drive 触发了严重的 Speed Deviation (when using a PG option card and AOLV/PM without PG) 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

Code type: Alarm / minor fault Manual section: Yaskawa A1000 Troubleshooting Load is too heavy Reduce the load. Acceleration and deceleration times are set too short. Increase the acceleration and deceleration times (C1-01 through C1-08). The load is locked up. Check the machine. Parameter settings are inappropriate. Check the settings of parameters F1-10 and F1-11. Incorrect speed feedback scaling if terminal RP is used as speed feedback input in V/f Control. - Set H6-02 to value of the speed feedback signal frequency when the motor runs at the maximum speed. - Adjust the speed feedback signal using parameters H6-03 through H6-05. - Make sure the speed feedback signal frequency does not exceed he maximum input frequency of terminal RP. The motor brake engaged. Ensure the brake releases properly.

Source: Yaskawa AC Drive A1000 High Performance Vector Control Drive Technical Manual (SIEP C710616 21H)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Yaskawa A1000 AC Drive 警报

由 Yaskawa 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 A1000 AC Drive 出现类似 dEv (Alarm) 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 280 Yaskawa A1000 AC Drive 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code dEv (Alarm).

Manual conversion service

Need a searchable reference for more Yaskawa A1000 AC Drive manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相关的 Yaskawa A1000 AC Drive 代码