代码 700106: Probe malfunction (table probe)
问题描述与安全警告
Chiron Siemens-Control CNC 触发了严重的 Probe malfunction (table probe) 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
The probe was not correctly switched on with the "Probe On (table probe) ( M187 )" function. Signal sequence for switch-on operation was incorrect. Probe was already directed out during switch-on. The error has the following effect: Feed Stop No axis movements possible. Read disable Control reads no further program blocks into memory. 1. Check probe. 2. Check interface (MI8) (switch setting, connection, etc.) 3. Check the following signals: PLC output signal "Enable measuring device". CNC input signals (SKIP) 4. Press [RESET] key. Message is cleared. Detailed information can be found in the chapter: Probe - TS27
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Chiron Siemens-Control CNC 警报
由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 700106 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 545 Chiron Siemens-Control CNC 代码s.