Code 700239: Tool not released (1)
Issue Description & Safety Warning
The Chiron Siemens-Control CNC has triggered a critical Tool not released (1) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Actuation "Unclamp tool" was output, but the response from the monitoring function for "Tool clamped" is not correct. The tool has not been correctly unclamped. Cause 1: The error has the following effect: Feed Stop No axis movements possible. Read disable Control reads no further program blocks into memory. If the sensor signals are correct within a monitoring period, the program run is continued. After the monitoring time has elapsed, the machine stops. 1. Check the actuation of the valves "Unclamp tool" and "Clamp tool". 2. Check sensors and corresponding PLC - input signals. 3. Check the voltage value of the analogue sensor. 4. Check the setting of the collet chuck and analogue sensor relative to the adjustment instructions. NOTICE! Adjustment should only be carried out by trained and instructed personnel. 5. As soon as the malfunction is remedied, press the following key: [FEED START] [CYCLE START] Message is cleared and the machining program can be continued. The command "Release tool“ has been output, but the "Tool clamped" pressure switch on the hydraulic unit signals still clamped. PLC input signal "Tool clamped“ is still present. If the messages are in order again within a monitoring time of about 8 seconds, the machine continues on immediately. After the monitoring time has elapsed, the machine stops. Cause 2 with hydraulic clamping system Error messages Tool change Tool not released (1) 1. Check "Tool clamped" pressure switch and the PLC input signal. 2. Check the PLC output signals and the actuation of the "Unclamp tool" and "Clamp tool“ valves.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Chiron Siemens-Control CNC Alarms
Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 700239 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 545 Chiron Siemens-Control CNC codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700239.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026