Code 700240: Tool not engaged in spindle (1)

Issue Description & Safety Warning

The Chiron Siemens-Control CNC has triggered a critical Tool not engaged in spindle (1) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

During the tool clamping operation, the "Tool engaged" sensor does not signal. Feed Stop Read disable If the signals are OK again within a certain monitoring time, the machine continues to run again immediately. After the monitoring time has elapsed, the machine stops and the error has to be acknowledged. Error messages Tool change Tool not engaged in spindle (1) Strategy procedure: The coupling speed is stopped briefly if the tool is not engaged after the tool changer has been moved down. Now it is attempted to engage with "stop & go". If engagement takes place during this time the machine continues operating. If, after this attempt, engagement is still unsuccessful, the machine stops with "Read-in disable". The protective equipment can now be unlocked by pressing the [Door Bypass button]. The door can be opened and the tool turned until it is engaged. Observe safety precautions. As soon as the tool is engaged now, the door must be closed and the machining program can be continued with the [CYCLE START] key. 1. Check the sensor and the PLC input signal "Tool engaged". 2. As soon as the malfunction is remedied, press one of the following keys: [FEED START] [CYCLE START] Message is cleared and the machining program can be continued. The diagnosis overview of the signals can be found under: Chapter 2.2 ‘Tool changer diagnostics menu’ on page 11

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Chiron Siemens-Control CNC Alarms

Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 700240 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 545 Chiron Siemens-Control CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 700240.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Chiron Siemens-Control CNC Codes