Code 701510: Oil/air lubrication malfunction! Negative pressure, vacuum suction nozzle, not present (spindle 2)

Issue Description & Safety Warning

The Chiron Siemens-Control CNC has triggered a critical Oil/air lubrication malfunction! Negative pressure, vacuum suction nozzle, not present (spindle 2) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

"Oil/air lubrication, vacuum suction nozzle valve on" was actuated, but there was no response from the "Oil/air lubrication, vacuum suction nozzle negative pressure available (SP2)" sensor within 5 seconds. The early warning of this malfunction was already signalled 100 hours ago, but within this time, the malfunction was not remedied. After the end of the program (M30, work area change), the machine stops. Feed STOP and Spindle STOP Read disable 1. Check the filter of the oil/air lubrication (contamination). 2. Check the actuation of the "Oil/air lubrication, vacuum suction nozzle valve on" valve. 3. Check the PLC input signal and the "Oil/air lubrication, vacuum suction nozzle negative pressure available (SP2)" sensor (sensor setting). 4. Check the functionality of the Venturi nozzle for generating negative pressure. 5. As soon as the malfunction is remedied, press one of the following keys: [FEED START] [CYCLE START] The menu can be found under: Chapter 2.6 ‘Oil/air lubrication’ on page 12

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Chiron Siemens-Control CNC Alarms

Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 701510 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 545 Chiron Siemens-Control CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 701510.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Chiron Siemens-Control CNC Codes