代碼 701538: Pre-warning, oil/air lubrication! Negative pressure, vacuum suction nozzle, not present (spindle 1/2)
問題描述與安全警告
Chiron Siemens-Control CNC 觸發了嚴重的 Pre-warning, oil/air lubrication! Negative pressure, vacuum suction nozzle, not present (spindle 1/2) 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
"Oil/air lubrication, vacuum suction nozzle valve on" was actuated, but there was no response from the "Oil/air lubrication, vacuum suction nozzle negative pressure available" sensor within 5 seconds. The early warning has no effects at first. Machining can continue for up to another 100 hours. The malfunction must be remedied within 100 hours. Otherwise, a malfunction message appears: Check the following components: 1. The filter of the oil/air lubrication (contamination). 2. The actuation of the "Oil/air lubrication, vacuum suction nozzle valve on" valve. 3. The PLC input signal and the "Oil/air lubrication, vacuum suction nozzle negative pressure available" sensor (sensor setting). 4. The functionality of the Venturi nozzle. The menu can be found under: Chapter 2.6 ‘Oil/air lubrication’ on page 12
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Chiron Siemens-Control CNC 警報
由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 701538 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 545 Chiron Siemens-Control CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 701538.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026