代码 SVGN-237: Position error:(Eq:%d,Ln:%d)

问题描述与安全警告

Fanuc R-30i Series Robot Controller 触发了严重的 Position error:(Eq:%d,Ln:%d) 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

Cause: Measured position error is greater than maximum allowable position error or less than min allowable position error." Remedy: Take the following actions. 1. Confirm the tip wear amount is correct. Re-execute the tip wear measurement when the tip wear amount is not correct. Note: if you take above action, re-execute the thickness check calibration. If this problem persists after taking the above actions, confirm that: 4.ERROR CODES B-83124EN-6/02 1. Max allowable Pos error (on gun teach setup screen) is large enough. 2. Min allowable Pos error (on gun teach setup screen) is small enough. If not, measured position error is made greater than min allowable position error and less than maximum allowable position error in the following ways. 1. Touch up correct position using jog or point touchup(not program touchup). 2. Increase maximum allowable position error or decrease min allowable position error on gun teach setup screen. Note: if initial position error is too large, program touchup cannot touch up. Fanuc recommends using point touchup(not program touchup) at the initial touchup. If this problem still persists after taking the above actions, take the following actions. 1. Confirm the position error offset in the spot program touchup setup screen. This alarm might be generated immediately after the position error offset is changed. 2. Confirm the parameter to correct position for Xgun in the spot program touchup setup screen. This alarm might be generated immediately after the parameter to correct position for Xgun is changed. If this problem persists after taking the all actions, perform the following actions: 1. Acquire the diagnostic data. See the procedure for diagnostic data collection at Troubleshooting section. 2. Contact your kocal FANUC representative.

Source: FANUC Robot R-30iA Alarm Code List Operator's Manual

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Fanuc R-30i Series Robot Controller 警报

由 Fanuc 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 R-30i Series Robot Controller 出现类似 SVGN-237 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 6553 Fanuc R-30i Series Robot Controller 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code SVGN-237.

Manual conversion service

Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相关的 Fanuc R-30i Series Robot Controller 代码