Código 201652: <location>SI CU: Illegal monitoring clock cycle

Descripción del problema y advertencia de seguridad

El Siemens SINUMERIK 840D CNC ha desencadenado una alarma crítica <location>SI CU: Illegal monitoring clock cycle. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.

Pasos oficiales de solución de problemas

Message value: %1 Drive object: SERVO, VECTOR Reaction: OFF2 Acknowledge: IMMEDIATELY (POWER ON) Cause: One of the Safety Integrated moni toring clock cycles is not permissible: - the drive-based monitoring clock cycle cannot be maintained due to the communication conditions required in the system. - the monitoring clock cycle for safe motion monitori ng functions with the high er-level control is not permissible (p9500). - The sampling time for the current controller (p0112, p0115) cannot be supported. Note: This fault results in a STOP A that cannot be acknowledged. Fault value (r0949, interpret decimal): - for enabled drive-based SI monitoring (p9601/p9801 > 0): Minimum setting for the monitoring clock cycle (in µs). - with the motion monitori ng function enabled (p9501 > 0): 100: No matching monitoring clock cycle was able to be found. 101: The monitoring clock cycle is not an integer mu ltiple of the actual value sensing clock cycle. 102: An error has occurred when transferring t he DP clock cycle to the Motor Module (MM). 103: An error has occurred when transferring t he DP clock cycle to the Sensor Module. 104,105: - four times the sampling time of the current contro ller is greater than 1 ms when operating with a nonclock-cycle synchr onous PROFIBUS. - Four times the sampling time of the current contro ller is greater than the DP clock cycle when operating with a clock-cycle synchronous PROFIBUS. - the DP clock cycle is not an integer multiple of the sampling time of the current controller. 106: The monitoring clock cycle does not matc h the monitoring clock cycle of the TM54F. 107: Four times the sampling time of the current co ntroller is greater than the actual value sensing clock cycle (p9511) or the actual value sensing cl ock cycle is not an integer multiple of the sampling time of the current controller. 108: The parameterized actual value sensing clock cycle cannot be set on this component SINAMICS-Alarms Remedy: For enabled drive-based SI monitoring (p9601/p9801 > 0): - upgrade the Control Unit software. For enabled motion monitoring function (p9501 > 0): - correct the monitoring clock cycle (p9500) and carry out POWER ON. Re fault value 101: - the actual value sensing clock cy cle is per default the position cont rol clock cycle / DP clock cycle. - for the drive-based motion monitoring functions (p9601/p9801bit 2 = 1) the actual value sensing clock cycle c an be directly parameterized in p9511/p9311. Re fault value = 104, 105: - set a separate actual val ue sensing clock cycle in p9511. - restrict operation to a maximum of two vector drives. For the standard settings in p0112, p0115, the current controller sampling time is automaticall y reduced to 250 µs. If the standard values were changed, then the current controller sampling time (p0112, p0115) should be appropriately set. - increase the DP clock cycle for operation with a clock-cycle synchr onous PROFIBUS so that there is a multiple clock cycle ratio of at least 4:1 betw een the DP clock cycle and the current controller sampling time. Re fault value 106: - set the parameters for the monitoring clock cycles the same (p10000 and p9500 / p9300). Re fault value 107: - set an actual value sensing cl ock cycle in p9511 that matches the current control clock cycle. Re fault value 108: - set a suitable actual value sensing clock cycle in p9511. - if, when operating with clock-cycle synchronous PR OFIBUS, the DP clock cy cle is used as actual value sensing clock cycle (p9511 = 0) a suit able DP clock cycle must be configured. A suitable multiple of the DP clock cycle (e.g. 1,2,3,4,5,6,8,10) must be parameterized on the D410. Otherwise, the clock cycle must be set to less than 8 ms. Note: CU: Control Unit MM: Motor Module SI: Safety Integrated

Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

Acerca de las alarmas de Siemens SINUMERIK 840D CNC

Los controladores industriales construidos por Siemens están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un SINUMERIK 840D CNC arroja un código de error como 201652, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.

Lista completa de alarmas: 4014 Siemens SINUMERIK 840D CNC códigos.

Have a better solution?

Help the industrial community by sharing your repair experience for code 201652.

Manual conversion service

Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Códigos relacionados de Siemens SINUMERIK 840D CNC