Código 700024: PLC-MD wrong (coolant)
Descripción del problema y advertencia de seguridad
El Chiron Siemens-Control CNC ha desencadenado una alarma crítica PLC-MD wrong (coolant). Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.
Pasos oficiales de solución de problemas
An inconsistency has been found between the coolant version used for the machine and the corresponding PLC machine data. The error has the following effect: Feed Stop No axis movements possible. Read disable Control reads no further program blocks into memory. 1. Match the PLC machine data to the coolant unit in use. 2. Turn off the control with the key [Control OFF] 3. Turn on the control with the key [Control ON] Message is cleared. This is a collective message. Error messages Cooling lubrication PLC-MD wrong (coolant) In the PLC status DB181.DBB2718, it is indicated which component or which PLC machine parameter has caused this message to appear. The corresponding bit, then, has a (1). In the following table, these bits are shown in more detail. DB Description DB181.DBB2718Bit 0 The coolant system “without high pressure“ is selected, but one of the "coolant high pressure" functions M7/M171-M177 was output. DB181.DBB2718Bit 1 A coolant system was activated which has no paperband filter, but the PLC input signal "Paperband filter present" is registered. DB181.DBB2718Bit 2 The coolant system "Without high pressure" was activated, but the PLC input signal "Clean water minimum" or "Superclean water minimum" is registered. DB181.DBB2718Bit 3 The PLC machine parameter "Without moisture sensor main spindle motor" was set, but the PLC input signal "Moisture sensor main spindle motor" is registered. DB181.DBB2718Bit 4 The coolant system "Without high pressure" was activated, but the PLC input signal "Coolant filter" is registered. DB181.DBB2718Bit 5 A PLC machine parameter "Without flow control device xxx" was set, but the PLC input signal "flow control device xxx" is registered. DB181.DBB2718Bit 6 DB181.DBB2718Bit 7
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Acerca de las alarmas de Chiron Siemens-Control CNC
Los controladores industriales construidos por Chiron están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un Siemens-Control CNC arroja un código de error como 700024, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.
Lista completa de alarmas: 545 Chiron Siemens-Control CNC códigos.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700024.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026