Back to all Siemens models Search all database
Siemens SINUMERIK 840D CNC
Siemens SINUMERIK 840D CNC Error Codes
Complete alarm and error code reference for the Siemens SINUMERIK 840D CNC. Browse all 4014 documented fault codes below, each linking to a detailed troubleshooting guide.
Search this section
Search Siemens SINUMERIK 840D CNC
Search all 4014 Siemens SINUMERIK 840D CNC codes without changing pages.
Complete Alarm List (Page 7 of 21)
Code 25060
Axis %1 speed setpoint limitation
View solution Code 25070
Axis %1 drift value too large
View solution Code 25080
Axis %1 positioning monitoring
View solution Code 25100
Axis %1 measuring system switchover not possible
View solution Code 25105
Axis %1 measuring systems differ considerably
View solution Code 25110
Axis %1 selected encoder not available
View solution Code 25200
Axis %1 requested se t of parame ters invalid
View solution Code 25201
Axis %1 drive fault
View solution Code 25202
Axis %1 waiting for drive
View solution Code 26000
Axis %1 clamping monitoring
View solution Code 26001
Axis %1 parameterization error: friction compensation
View solution Code 26002
Axis %1 encoder %2 parameterization error: number of encoder marks
View solution Code 26003
Axis %1 parameterization error: lead screw pitch
View solution Code 26004
Axis %1 encoder %2 parameterization error: grid point distance with linear encoders
View solution Code 26005
Axis %1 parameteriza tion error: output rating
View solution Code 26006
Axis %1 encoder %2 encoder type/output type %3 not possible
View solution Code 26007
Axis %1 QEC: invalid coarse step size
View solution Code 26008
Axis %1 QEC: invalid fine step size
View solution Code 26009
Axis %1 QEC: memory overflow
View solution Code 26010
Axis %1 QEC: invalid acceleration characteristic
View solution Code 26011
Axis %1 QEC: in valid measuring periods
View solution Code 26012
Axis %1 QEC: feed forward control not active
View solution Code 26014
Axis %1 machine data %2 invalid value
View solution Code 26015
Axis %1 machine data %2[%3] invalid value
View solution Code 26016
Axis %1 machine data %2 invalid value
View solution Code 26017
Axis %1 machine data %2[%3] invalid value
View solution Code 26018
Axis %1 setpoint output drive %2 used more than once
View solution Code 26019
Axis %1 encoder %2 measurement not possible with this controller module
View solution Code 26022
Axis %1 encoder %2 measurement with simulated encoder not possible
View solution Code 26024
Axis %1 machine data %2 value changed
View solution Code 26025
Axis %1 machine data %2[%3] value changed
View solution Code 26026
Axis %1 SINAMICS drive parameter P2038 value is not allowed.
View solution Code 26030
Axis %1 encoder %2 absolute position lost
View solution Code 26031
Axis %1 configuration error master-slave
View solution Code 26032
[Channel %1: ] Axis %2 master-slave not configured
View solution Code 26050
Axis %1 parameter set change from %2 to %3 not possible
View solution Code 26051
[Channel %1: ] In block %2 unanticipated stop crossed in continuous path mode
View solution Code 26052
[Channel %1: ] In block %2: path velocity too high for auxiliary function output
View solution Code 26053
[Channel %1: ] Block %2 interpolation problem in Look Ahead (module %3, identifier %4)
View solution Code 26054
[Channel %1: ] Block %2 interpolation warning in Look Ahead (module %3, problem %4)
View solution Code 26070
[Channel %1: ] Axis %2 cannot be controlled by the PLC, max. number exceeded
View solution Code 26072
[Channel %1: ] Axis %2 cannot be controlled by the PLC
View solution Code 26074
[Channel %1: ] Switching off PLC control of axis %2 not allowed in the current state
View solution Code 26075
[Channel %1: ] Axis %2 not available for the NC program, as exclusively controlled by the PLC
View solution Code 26076
[Channel %1: ] Axis %2 not available for NC program, firmly assigned PLC axis
View solution Code 26100
Axis %1 drive %2 sign of life missing
View solution Code 26101
Axis %1 drive %2 communication failure
View solution Code 26102
Axis %1 drive %2 sign of life missing
View solution Code 26105
Drive of axis %1 not found
View solution Code 26106
Encoder %2 of axis %1 not found
View solution Code 26120
[Channel %1: ] Axis %2 $AA_ESR_ENABLE = 1 but axis should be set to NEUTRAL
View solution Code 26121
[Channel %1: ] Axis %2 is NEUTRAL and $AA_ESR_ENABLE = 1 should be set
View solution Code 26122
[Channel %1: ] Axis %2, $AA_ESR_ENABLE = 1, axis exchange not executed in this state
View solution Code 26123
[Channel %1: ] Axis %2, $AA_ESR_ENABLE = 1 should be set, but MD37500 $MA_ESR_REACTION = 0
View solution Code 26124
[Channel %1: ] Axis %2, $AC_ESR_TRIGGER triggered but axis is NEUTRAL and cannot execute ESR
View solution Code 26200
[Channel %1: ] Block %2: The names of the kinematic chains $NK_CHAIN_NAME[%3] and $NK_C HAIN_NAME[%4] are the same]
View solution Code 26202
[Channel %1: ] Block %2: The names of the kinematic chain links $NK_NAME[%3] and $NK_NAME[%4] are the same]
View solution Code 26204
[Channel %1: ] Block %2: The chain element %3 referred to in $NK_NEXT[%4] is already contained in the chain
View solution Code 26206
[Channel %1: ] Block %2: The chain element %3, referred to in $NK_1ST_ELEM[%4], was not found
View solution Code 26208
[Channel %1: ] Block %2: Chai n element %3, referred to in $NK_NEXT[%4], was not found
View solution Code 26210
[Channel %1: ] Block %2: Chain %3, referred to in $NK_NEXTP[%4], was not found
View solution Code 26212
[Channel %1: ] Block %2: Maximum number of %3 chain elements exceeded
View solution Code 26214
[Channel %1: ] Block %2: The maximum permissible value of fine offset in chain element %3 was exceeded
View solution Code 26216
[Channel %1: ] Block %2: The axis direction in chain element %3 has not been defined.
View solution Code 26218
[Channel %1: ] Block %2 : Invalid name in %3[%4]
View solution Code 26222
[Channel %1: ] Block %2: The names of the protection areas $NP_PROT_NAME[%3] and $NP_ PROT_NAME[%4] are the same
View solution Code 26224
[Channel %1: ] Block %2: The names of the protection area elements $NP_NAME[%3] and $NP_NAME[%4] are the same
View solution Code 26226
[Channel %1: ] Block %2: Invalid pr otection area type in $NP_TYPE[%3]
View solution Code 26227
[Channel %1: ] Block %2: CAD fi le not found: %3
View solution Code 26228
[Channel %1: ] Block %2: The protection area element %3, referred to in $NP_1ST_PROT[%4], was not found
View solution Code 26230
[Channel %1: ] Block %2: Protection area element %3, referred to in $NP_NEXT[%4], was not found
View solution Code 26231
[Channel %1: ] Block %2: The protection zone or the CAD file %3 referred to in $TC_TP_PROTA[%4] was not found.
View solution Code 26232
[Channel %1: ] Block %2: Maximum number of %3 protection area elements exceeded
View solution Code 26233
[Channel %1: ] Block %2: The maximum permissible number of tool protection zone elements has been exceeded.
View solution Code 26234
[Channel %1: ] Block %2: The protection area $NP_PROT_NAME[%3] does not contain any protection area elements
View solution Code 26236
[Channel %1: ] Block %2: Protection area element %3, referred to in $NP_NEXT[%4], is already contained in the definition chain
View solution Code 26238
[Channel %1: ] Block %2: Protection area %3, referred to in $NP_ADD[%4], was not found
View solution Code 26240
[Channel %1: ] Block %2: The protection area indicated in $NP_ADD[%3] is linked with a kinematic chain
View solution Code 26241
[Channel %1: ] Block %2: The tool protection zone %3 ($NP_PROT_NAME[%4]) contains a reference to a kinematic chain.
View solution Code 26242
[Channel %1: ] Block %2: Name of the kinematic chain in $NP_CHAIN_NAME[%3] not defined
View solution Code 26244
[Channel %1: ] Block %2: Protection area %3, referred to in $NP_ADD[%4], is already contai ned in the definition chain
View solution Code 26246
[Channel %1: ] Block %2: Para meter $NP_PARA[%3,%4] is invalid
View solution Code 26248
[Channel %1: ] Block %2: The contents (%4) of parameter $NP_BIT_NO[%3] are invalid
View solution Code 26250
[Channel %1: ] Block %2: The names of the protection area groups $NP_NAME[%3] and $NP_NAME[%4] are the same
View solution Code 26252
[Channel %1: ] Block %2: Element %4 of the protection area group %3 is not linked with a kinematic chain
View solution Code 26254
[Channel %1: ] Block %2: The protection area referred to in element %4 of protection area group %3 was not found
View solution Code 26256
[Channel %1: ] Block %2: The protection area group %3 referred to in $NP_ADD_GROUP[%4] was not found
View solution Code 26260
[Channel %1: ] Block %2: Collision of the two protection areas %3 and %4
View solution Code 26261
[Channel %1: ] The two protection zones %2 and %3 collide
View solution Code 26262
[Channel %1: ] Not enough memory space during collision test of the two protection zones %2 and %3. Current ly available memory space: %4KB.
View solution Code 26263
[Channel %1: ] Block %2: Not enough memory space for determining the distance between two protection zones. Currently available memory space: %3KB.
View solution Code 26264
[Channel %1: ] Block %2: The protection area with the name %3 was not found.
View solution Code 26266
[Channel %1: ] Block %2: The protection area with the name %3 was programmed several times.
View solution Code 26268
[Channel %1: ] Block %2: Protection area %3 has not been assigned an interface bit
View solution Code 26270
[Channel %1: ] Block %2: Invaid activation parameter during the PROTA function call
View solution Code 26272
[Channel %1: ] Block %2: The contents (%3) of parameter $NP_INIT_STAT[%4] are invalid
View solution Code 26274
[Channel %1: ] Block %2: Chain %3 referred to in $NP_CHAIN_NAME[%4] was not found
View solution Code 26276
[Channel %1: ] Block %2: Chain element %3 referred to in $NP_CHAIN_ELEM[%4] was not found
View solution Code 26278
[Channel %1: ] Block %2: The axis or frame name %3 contained in $NK_AXIS[%4] is unknown
View solution Code 26280
[Channel %1: ] Axis %2 risk of collision %3 %4
View solution Code 26281
[Channel %1: ] Axis %2 risk of collision %3 %4
View solution Code 26282
[Channel %1: ] Block %2: Invalid definition of the protection zones or the kinematic chains.
View solution Code 26284
[Channel %1: ] Block %2: The call of the function / procedure %3 is only permissible if the function 'C ollision monitoring' is present.
View solution Code 26286
[Channel %1: ] Axis %2 risk of collision preactivated protection zones interface signal(s) %3
View solution Code 26290
[Channel %1: ] Block %2: Maximum number of %4 protection zone facets exceeded in CAD file %3
View solution Code 26292
[Channel %1: ] Block %2: Maximum number of %4 input points exceeded in CAD file %3
View solution Code 26294
[Channel %1: ] Block %2: CAD file %3 is not a valid VRML file
View solution Code 26296
[Channel %1: ] Block %2: CAD fi le %3 is not a valid STL file
View solution Code 27000
Axis %1 is not safely referenced
View solution Code 27001
Axis %1 error in a monitoring channel, code %2, values: NCK %3, drive %4
View solution Code 27002
Axis %1 test stop is running
View solution Code 27003
Checksum error found: %1 %2
View solution Code 27004
Axis %1, difference safe input %2, NCK %3, drive %4
View solution Code 27005
Axis %1 error in data cross check: static actual value difference
View solution Code 27006
Axis %1 Test ext. pulse deletion running
View solution Code 27007
Axis %1 acceptance test mode is active
View solution Code 27008
Axis %1 SW limit switch deactivated
View solution Code 27010
Axis %1 tolerance for safe standstill exceeded
View solution Code 27011
Axis %1 safe velocity exceeded
View solution Code 27012
Axis %1 safe end position exceeded
View solution Code 27013
Axis %1 Safe monitoring for acceleration exceeded
View solution Code 27020
Axis %1 stop E triggered
View solution Code 27021
Axis %1 stop D triggered
View solution Code 27022
Axis %1 stop C triggered
View solution Code 27023
Axis %1 stop B triggered
View solution Code 27024
Axis %1 stop A triggered
View solution Code 27030
Axis %1 function not supported on this SIMODRIVE611D module
View solution Code 27031
Axis %1 limit value for safe velocity %2 at gear ratio %3 too large (max. %4)
View solution Code 27032
Axis %1 checksum error of safe monitoring. Confirmation and acceptance test required.
View solution Code 27033
Axis %1 parameterizati on of MD %2[%3] invalid
View solution Code 27034
Parameterization of MD %1[%2] invalid.
View solution Code 27035
Axis %1 new hardware component, confirmation and functional test required.
View solution Code 27036
Axis %1 encoder parameterization MD %2[%3] has been adjusted.
View solution Code 27037
Axis %1 and %2 with the same PROFIsafe address %3.
View solution Code 27038
Axis %1 value %2 in drive parameter %3 violates the limits of NCK MD %4.
View solution Code 27039
Axis %1 parameterization MD %2[%3] changed, confirmation and functional test required.
View solution Code 27040
Axis %1 waiti ng for motor module.
View solution Code 27050
Axis %1 SI communication failure.
View solution Code 27060
Axis %1 Drive assignment checksum error. Confirmation and acceptance test required!
View solution Code 27070
Checksum error parameterization SPL and SPL interfaces. Confirmation and acceptance test required!
View solution Code 27071
Checksum error safe PLC para meterization. Confirmation and acceptance test required!
View solution Code 27072
Checksum error enable safe communication. Confirmation and acceptance test required!
View solution Code 27073
Checksum error S7 PROFIsafe configuration. Confirmation and acceptance test required!
View solution Code 27090
Error in data cross check NCK-PLC, %1[%2], NCK: %3; %4<ALSI>
View solution Code 27091
Error in data cross check NCK-PLC, stop of %1
View solution Code 27092
Communication broken off during NCK PLC data cross check, error detected by %1
View solution Code 27093
Checksum error NCK-SPL, %1, %2, %3
View solution Code 27094
Write access to system variable %1 only allowed from NCK-SPL
View solution Code 27095
%1 SPL protection not activated
View solution Code 27096
SPL start not allowed
View solution Code 27097
SPL start not executed
View solution Code 27098
SPL commissioning phase terminated
View solution Code 27099
Double assignment in SPL assignment MD %1[%2] - MD %3[%4]
View solution Code 27100
At least one axis is not safely referenced
View solution Code 27101
Axis %1 difference in function safe operational stop, NCK: %2 drive: %3
View solution Code 27102
Axis %1 difference in function safe velocity %2, NCK: %3 drive: %4
View solution Code 27103
Axis %1 difference in function safe limit position %2, NCK: %3 drive: %4
View solution Code 27104
Axis %1 difference in function safe cam plus %2, NCK: %3 drive: %4
View solution Code 27105
Axis %1 difference in function safe cam minus %2, NCK: %3 drive: %4
View solution Code 27106
Axis %1 difference in function safe velocity nx, NCK: %2 drive: %3
View solution Code 27107
Axis %1 difference in function cam modulo monitoring, NCK: %2 drive: %3
View solution Code 27110
Axis %1 fault during data transmission index%2.
View solution Code 27111
Axis %1 fault during encoder evaluation of the safe actual value.
View solution Code 27112
Axis %1 CRC error of the safe actual value.
View solution Code 27113
Axis %1 hardware encoder error of the safe actual value.
View solution Code 27124
Stop A triggered at least in 1 axis
View solution Code 27140
Waiting for motor module of at least one axis.
View solution Code 27200
PROFIsafe: cycle time %1 [ms] too long
View solution Code 27201
PROFIsafe: MD %1[%2]: bus segment %3 error
View solution Code 27202
PROFIsafe: MD %1[%2]: address %3 error
View solution Code 27203
PROFIsafe: MD %1[%2]: SPL assignment error
View solution Code 27204
PROFIsafe: double assignment MD %1[%2] - MD %3[%4]
View solution Code 27205
PROFIsafe: number of signals in MD %1 [%2] <> MD %3[%4]
View solution Code 27206
PROFIsafe: MD %1[%2] maximum number of F user data (%3 bits) exceeded.
View solution Code 27207
PROFIsafe: MD %1[%2] max. sub slot number: %3 exceeded
View solution Code 27208
PROFIsafe: MD %1[%2]: max. sub-slot address %3 exceeded.
View solution Code 27220
PROFIsafe: Number of NCK F modules (%1) <> Number of S7 F modules (%2)
View solution Code 27221
PROFIsafe: NCK F module MD %1[%2] unknown
View solution Code 27222
PROFIsafe: S7 F module PROFIsafe address %1 unknown
View solution Code 27223
PROFIsafe: NCK F module MD %1[%2] is not a %3 module
View solution Code 27224
PROFIsafe: F module MD %1[%2] - MD %3[%4]: double assignment of PROFIsafe address
View solution Code 27225
PROFIsafe: slave %1, configuration error %2
View solution Code 27240
PROFIsafe: DP M not running up, DP info: %1
View solution Code 27241
PROFIsafe: DP M version different, NCK: %1, PLC: %2
View solution Code 27242
PROFIsafe: F module %1, %2 faulty
View solution Code 27250
PROFIsafe: configur ation in DP M changed; error code %1 - %2
View solution Code 27251
PROFIsafe: F module %1, %2 reports error %3
View solution Code 27252
PROFIsafe: Slave %1, sign-of-life error
View solution Code 27253
PROFIsafe: communication faul t F master component %1, error %2
View solution Code 27254
PROFIsafe: F module %1, error on channel %2; %3<ALSI>
View solution Code 27255
PROFIsafe: F module %1, general error
View solution Code 27256
PROFIsafe: Current cycle time %1 [ms]> parameterized cycle time
View solution Code 27257
PROFIsafe: %1 %2 re ports system error %3 (%4)
View solution Code 27299
PROFIsafe: Diagnostics %1 %2 %3 %4
View solution Code 27300
F_DP: Cycle time %1 [ms] is too long
View solution Code 27301
F_DP: MD %1[%2]: SPL interface faulty
View solution Code 27302
F_DP: Double assignment MD %1[%2] - MD %3[%4]
View solution Code 27303
F_DP: Number of signals in MD %1 [%2] <> MD %3[%4]
View solution Code 27305
F_DP: Parameter MD %1 [%2] <> MD %3[%4]
View solution Code 27306
F_DP: Maximum number of active SPL connections (%1) exceeded for %2.
View solution